============================================================================= Intel(R) Server Platform S2600BP FRU/SDR Update Release Notes ============================================================================= INTEL Enterprise Platform & Services Marketing Intel Corporation 2111 N.E. 25th Avenue, Hillsboro, OR 97124 USA ============================================================================= DATE: Oct 10, 2022 TO: Intel(R) Server Platform S2600BP customers SUBJECT: IBMC(R) FRU/SDR update package S2600BP_FRUSDR_149 release notes ============================================================================= LEGAL INFORMATION ============================================================================= Information in this document is provided in connection with Intel products. No license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document. Except as provided in Intel's Terms and Conditions of Sale for such products, Intel assumes no liability whatsoever, and Intel disclaims any express or implied warranty, relating to sale and/or use of Intel products including liability or warranties relating to fitness for a particular purpose, merchantability, or infringement of any patent, copyright or other intellectual property right. Intel Corporation may have patents or pending patent applications, trademarks, copyrights, or other intellectual property rights that relate to the presented subject matter. The furnishing of documents and other materials and information does not provide any license, express or implied, by estoppel or otherwise, to any such patents, trademarks, copyrights, or other intellectual property rights. Intel products are not intended for use in medical, life saving, or life sustaining applications. Intel may make changes to specifications and product descriptions at any time, without notice. Intel is a registered trademark of Intel Corporation. *Other names and brands are the property of their respective owners. Copyright (c) 2022 Intel Corporation. ============================================================================= ABOUT THIS RELEASE PACKAGE ============================================================================= SDR file version: 1.49 SDR data based on system/thermal team SDR spreadsheet BNP FSC Auto-SDR Config Sheet rev2.4_Candidate.xlsm (20210108) FRUSDR Tools: FRUSDR_V14_1_Build18_AllOS.zip ============================================================================= SYSTEM HARDWARE & SOFTWARE REQUIREMENTS/REVISIONS ============================================================================= - S2600BPB,S2600BPQ,S2600BPS,S2600BPL,S2600BPC baseboard. - BMC FW 2.42 or later - Front Panel, Hot-swap backplane, and Baseboard FRU data must be available for chassis auto-detection to succeed. ============================================================================= IMPORTANT INSTALLATION NOTES ============================================================================= NOTE: If you updated BIOS and did not clear CMOS Ram, you should do that before installing this package. ============================================================================= INSTALLATION PROCEDURE ============================================================================= 1. Ensure BMC FW release 2.42 or later is pre-installed before attempting this FRU/SDR update. 2. Copy all of the files and directories in the S2600BP_FRUSDR_149.zip archive to a USB key, hard disk drive or floppy drive. 3. Run command FRUSDR.EFI /fru S2600BPx.fru to update baseboard FRU to BMC. S2600BPB.fru : for Buchanan Pass LBG 1G Dual 10G Mother board S2600BPQ.fru : for Buchanan Pass LBG L Dual 10G Mother board S2600BPS.fru : for Buchanan Pass SFP+ LBG-2 Dual 10G Mother board S2600BPL.fru : for Buchanan Pass LBG 1G/L Dual 10G Mother board with Liquid cooling S2600BPC.fru : for Buchanan Pass LBG Mother board with coolIT solution 4. Execute the following script to bring up the main FRU/SDR load menu: updS2600BP.nsh 5. Select Option 1 to do the SDR update. 6. Answer the prompts, and the SDRs will be loaded ============================================================================= KNOWN ISSUES/WORKAROUNDS ============================================================================= "FRUSDR.EFI /d fru" or ipmitool fru list cannot dump BMC FRU before SDR updated. ============================================================================= ISSUES FIXED ============================================================================= S2600BP_149 - 15012037399 change the BIOS Sensor from "ADDDC Error" to "ADDDC VLS Event". S2600BP_148 - 15010443289 [Purley][BMC]wrong chassis information in frusdr - update BIOS sensor according to BIOS EPS v1.19 S2600BP_147 -update BIOS sensor number according to BIOS EPS v1.18 - HSD 1509288822 -Wolf Pass (S2600WFT) uses the wrong entity ID for the sensor "NVMe 1 Therm Mgn" S2600BP_145 -update FRUSDR utility to FRUSDR_V14_1_Build18_AllOS.zip S2600BP_144 -2103631992 The BMC EWS WebUI copyright date still shows the 2019 year. S2600BP_143 -sync BIOS sensor definition as BIOS EPS v1.13 "table41. BIOS sensors and SEL data" for HSD1507429379 S2600BP_142 -remove two BIOS sensor "UPI Fatl Sensor" for no definition in BIOS EPS v1.13 S2600BP_141 -Update frusdr.efi, frusdr_temp.efi ipmi.efi into FRUSDR_V14_1_Build17_AllOS S2600BP_139 -1506769657 Sel log appear “Cooling Device Sys Pump 2 | Lower Non-critical going low | Asserted” during AC cycles S2600BP_138 -1506677406 Only cover fan domain 0/1 in SDR for other chassis -1506527273 SDR record failure S2600BP_137 -2103622131 When retrieve the "P1/P2 Temperature" threshold by command or EWS, it shows "00" or "NA" -2203243919 [BNP] 1 of 2000 nodes failed for intermittent +1.05V_PCH_Aux SEL event, crossing upper non-critical threshold S2600BP_135 S2600BP_134 S2600BP_133 -Rename QPI sensor name from QPI to UPI S2600BP_132 S2600BP_131 S2600BP_130 S2600BP_129 -Fix H2212 with S2600BPL show 1 HDD only S2600BP_128 -Update FRUSDR tool to v14.1 build 11 -2103619781 S2600BPB SEL events reports Voltage BB +12.0V Upper Non-critical going high S2600BP_127 -2103619738 S2600BPB Voltage Voltage Fault reported during DC cycle and SAT FIO testing -2103619391 It will generate the "Exit Air Temp" log when on-line update the BMC with certain types of Link-Board -2201182147 4 of 4391 nodes failed for intermittent "VNN PCH Aux" SEL event, crossing upper non-critical threshold S2600BP_126 -1504473313.44: [FTF]Fan Boost value do not reach expected value during running FSC BAT_FSC_Functional_004.tcl test S2600BP_125 -220855900 [BNP] 4 of 3052 nodes failed for intermittent +1.8V PCH Aux SEL event, crossing upper non-critical threshold -220855434 [BNP] 9 of 3052 nodes failed for intermittent +3.3v (non vbat) SEL event, crossing upper non-critical threshold S2600BP_124 -1504572530 The thresholds for Pump RPM of High CT and High NC are not setting in BMC Threshold List -1504560008 No FAN Control Profile (lower bank) support during FSC record test on liquid cooling SKU -1504536167 "Chassis auto-detect error" on FRUSDR update with non-intel chassis - Fix "LSI3008 Temp" will show up for "Other" chassis problem. S2600BP_123 S2600BP_105 S2600BP_104 -1504469586 FTF script SDR_Hysteresis_Check.tcl test failed on BNP S2600BP_103 S2600BP_100 S2600BP_049 - Fix PSU1 FAN1 Fail string length problem. S2600BP_048 -1209356456 Power supply fan sensor status is not correct when physically stopped. -1504469586 FTF script SDR_Hysteresis_Check.tcl test failed on BNP S2600BP_047 - 1504467693 "PS Fan Fail" show "Not Available" on EWS with FRUSDR 0.46 - Remove the solution for 1209356456 Power supply fan sensor status is not correct when physically stopped BMC fw need to update also S2600BP_046 - 1209356456 Power supply fan sensor status is not correct when physically stopped BMC fw need to update also S2600BP_045 S2600BP_044 - Follow FSC Auto-configuration sheet 1.0 to modify Global Clamp Records (P1 DTS Margin & P2 DTS Margin) - Fix 1504412435 Some sensor healthy show unknown on E-BCP units - Fix 2103614885 Updated EBCP FRU successful, but could not see any information in WEBUI FRU info page. S2600BP_043 - Fix Agg Therm Margn 2 display unknown problem. S2600BP_042 S2600BP_041 - Update FRUSDR tool to v14.1 build 8 - Fix EPSD100256791 fru file name show incorrect when updating FRUSDR S2600BP_040 - To enable PSUx realted sensor for unsupported PSU Add tag 'STICKY_PSx' for each PSx related SDR record S2600BP_039 - fix EPSD100035320 sometimes sensor "Exit Air Temp" show Upper Critical. S2600BP_038 - Remove P0V83_LAN_AUX SDR record from SFP+ sku - Update frusdr.efi, frusdr_temp.efi ipmi.efi from FRUSDR_V14_1_Build7_AllOS - Remove BB MISC VR Temp SDR record from SFP+ sku - Add OEM NM SDR record to fix "external management software can't find ME" issue S2600BP_037 - Add OEM Voltage related sensor record. S2600BP_036 - Remove PSx FAN2 sensor -Add oem record 1F to identify 24HDD system - Add Tag to remnove LAN NIC Temp Sensor for S2600BPS board S2600BP_035 - Modify NVMe 1 Crit Warn sensor number to 0x94 S2600BP_034 - Add OS event sensor S2600BP_033 - Modify Entity ID for BB Inlet Temp S2600BP_032 - Modify event mask and sensor unit for Px Therm Ctrl S2600BP_031 - EPSD100033928 There is no sensor "SSB temp" and "SSB Thermal Trip" in FRUSDR 024. - EPSD100031955 The "SSB Temp" 0x22 sensor shows its reading is "0 degrees C" in the EWS or read by cmdtool Note : PCH must be B0/B1 to verify this issue. S2600BP_030 - EPSD100254450 can't adjust fan speed for system fan 6 and 7 with IPMI command S2600BP_029 - Add "Test Plate" in "Fan Sensor Domain Map" record - Independent sensor 36,37 to Domain 6,7 in "Fan Sensor Domain Map" record. - Change "Event/Reading Base Type" of "NVMe 1 Crit Warn" sensor from 6F to 73. - Update VBT and +12V sensors SDR content. S2600BP_028 - Modify the FAN's M value to avoid overflow problem - Add SYSTEM_FAN_6/7 question for "TEST_PLATE" configuration. And to add FAN6, FAN7 SDR record if FAN 6 or FAN 7 populated. - Add OTHER_FAN_6/7 question for "OTHER" configuration. And to add FAN6,FAN7 SDR record, if FAN 6 or FAN 7 populated. S2600BP_027 - Modify FSC version from 02 to 03 for clamp header ID 94 & 95 - Change Lower non-critical value of SYSTEM_FAN_XB from C to D - Correct Clamp Temperature for Sensor Number 75 - Change value of "Test Plate"'s stepwise curve ID from decimal to hexadecimal - Correct record size over 64 bytes problem for "Test Plate" S2600BP_026 - EPSD100252903 sensor "LSI3008 Temp" Not Readable on EWS BMC F/W version must be 0.29 or later - enable NMI button for "OTHER" and "TEST_PLATE" case S2600BP_025 - Correct OEM SDR record, FSC subtype 4 record to add back Domain 4~7 record - Force 3008 temp sensor to enable when node insert into 12 HDD chassis (Side effect, 3008 temp sensor will present if SATA bridge board populated) S2600BP_024 - Remove SSB temp and SSB thermal trip record - Modify Reading Mask & Settable / Readable Threshold Masks for Px DTS Therm Mgn Record S2600BP_023 - Remove 3008 VR Temp sensor and Add 3008 Temp sensor for 4Port 12G SAS down Bridge board - Tune Global Clamp record to make FAN speed up early S2600BP_022 - EPSD100033530 Modify PS1/2 Input Power M value from 0B to 0D Event/Reading Bae Type for sensor 'NVMe 1 Crit Warn' change to 6F - Add NVMe 1 Therm Mgn,NVMe 1 Crit Warn sdr record S2600BP_021 - EPSD100033195 Modify FAN's m value S2600BP_020 S2600BP_019 - EPSD100253348 OEM Record Version is incorrect for FSC record type 0x02/0x01/0x08 - EPSD100253350 The Exit Air Temp record is incorrect for FSC record checking - EPSD100032207 No LAN Leash Lost event in SEL - EPSD100252903 sensor "LSI3008 Temp" Not Readable on EWS - Modify Event and Reading mask for P1/P2 Status - Modify Event and Reading mask for MTT CPU1 S2600BP_018 - To correct EVENT Mask and Reading mask for MTT CPU1/2 - EPSD100253010 [BNP,WFP]OFU_V14_1_Build4:The string of "Entering BMC Update Mode..." should be placed on a new line when update BMC&Fursdr. - EPSD100032697 There is no threshold value for processor therm margin. - EPSD100253239 sensor "CATERR" Not Readable on EWS - EPSD100032850 The threshold of sensor "P1/P2 Therm Ctrl%" shows NA. - EPSD100252903 sensor "LSI3008 Temp" Not Readable on EWS - EPSD100252904 sensor "LSI3008 VR Temp" Not Readable on EWS - EPSD100033031 Detect "LSI 3408 Temp" and "LSI3008 Temp" sensor in sensor reading page on EWS. S2600BP_017 -EPSD100253105 All thresholds for 'HSBP temp' and 'Front Panel temp' show "N/A" in the "Sensor Readings" page -Update Assertion Event Mask,Deassertion Event Mask and Reading Mask & Settable / Readable Threshold Masks for temperature sensor. S2600BP_016 -EPSD100253010 [BNP,WFP]OFU_V14_1_Build4:The string of "Entering BMC Update Mode..." should be placed on a new line when update BMC&Fursdr. -EPSD100032565 FRU information not display correctly in EWS. -EPSD100032575 Use H2224 chassis, it does not show the "HS Backplane" FRU information in the FRU Information menu -Modify IPMI Watchdog Assertion Event Mask from 0000 to 0F01 -Update sensor 'BB +12.0V' Event Mask and Reading Mask -Remove duplicate sensor "Front Pannel Temp" S2600BP_015 EPSD100252916 FRUSDR can be updated by using other platform's FRUSDR EPSD100252921 FRU version show incorrect after issue EFI command "frusdr.efi /d fru" S2600BP_014 S2600BP_013 S2600BP_012 - Fix incorrect sdr record for TEST_PLATE config - Add tag to prevent "Clamp header with non-existing THERMOMETER" message when no LSI SAS 3008/3408 populated - Remove PROCESSOR_2 Tag for BB MISC VR Temp record. S2600BP_011 -EPSD100031854 In EWS, the senosr name of "power supply deasserted" event shows "#50" -EPSD100252507 All SDR records have the same record ID 0x0000 -EPSD100031967 In "EWS > FRU information" , it has duplicate option of baseboard , HSBP and PSU. (screenshot) -EPSD100031971 Since BuchananPass doesn't support SAS/IO module, it should not list the "IO/SAS Mod Presence" sensor in list.(screenshot) S2600BP_010 -EPSD100031860 The FruSdr version and Copyright information should be updated in the release note and master.cfg files S2600BP_009 -EPSD100031940 It doesn't support the "H2216 chassis", but it list in the menu in master.cfg -EPSD100031942 [BNP_BMC] System auto shutdown (idle mode at 25C) after update BIOS D097 + BMC 11 + SDR 06 or 07 -EPSD100031897 The copyright year in master.cfg shows "2015". -EPSD100031860 The FruSdr version and Copyright information should be updated in the release note and master.cfg files -EPSD100031826 The BMC WebUI shows the SDR version is: "0.05" or "0.06" after update the FruSdr_0.07 version -EPSD100251399 Clone of: FRUSDR_V14_1_Build1:SDR version showed as "-" in BIOS F2 Screen S2600BP_007 -Correct BB Inlet Temp,Exit Air Temp Sensor unit2 -Remove All TAG for Front Panel temp -Correct FSC Record type for Global Stepwise Records -Remove duplicate Record S2600BP_006 S2600BP_005 -EPSD100031306 In the SDR file of FRUSDR 002, the version still shows 0.1. (It should be 0.2.) -fix BMC can't detect ps2 when it update SDR S2600BP_004 -EPSD100031306 In the SDR file of FRUSDR 002, the version still shows 0.1. (It should be 0.2.) -EPSD100031316 The Master.cfg file in S2600BP_002 package shows the FruSdr version is S2600BP_001 -Correct HSBP TEMP B parameter -Add _SDR_TAG 'BCP_2U4N' to Agg Therm Mrgn 1 -Modify some no leading 0 issue on _REC_LEN -Fix incorrect _SDR_TAG issue for HSBP temp sensor -Correct BB BMC TEMP,BB CPU1 VR TEMP,BB CPU2 VR TEMP unit S2600BP_002 -EPSD100030984 When updating FRUSDR, it will show "null string" in the first line. (screenshot) S2600BP_0.1: - First release ============================================================================= FEATURES ADDED ============================================================================= S2600BP_146 -add new SKU S2600BPC for CCB3257 "Buchanan Pass CoolIT Product Integration" S2600BP_142 -Add sensor "eSPI Reg Access" for feature "BMC eSPI register access restriction" S2600BP_140 -Add sensor "KCS Policy" for feature "KCS policy control mode" S2600BP_138 -Add 2Port PE Bridge Board FRU support -Implement BNP FSC Auto-SDR Config Sheet rev2.1_Candidate.xlsm (20180829) -Implement BNP FSC Auto-SDR Config Sheet rev2.0_Candidate.xlsm (20180824) S2600BP_137 S2600BP_135 -Implement BNP FSC Auto-SDR Config Sheet rev1.9_Candidate.xlsm (20180328) S2600BP_134 -Implement BNP FSC Auto-SDR Config Sheet rev1.8_Candidate.xlsm (20180306) -Add Remote Debug SDR record -Add FW Security SDR record S2600BP_133 S2600BP_132 -Add P1 Temperature and P2 Temperature SDR record S2600BP_131 -Implement BNP FSC Auto-SDR Config Sheet rev1.7_draft.xlsm (20180102) -Add Liquid cooling 24HDD SKU support S2600BP_130 S2600BP_129 S2600BP_128 S2600BP_127 -Implement BNP FSC Auto-SDR Config Sheet rev1.6_candidate.xlsm (20171110) S2600BP_126 -Implement BNP FSC Auto-SDR Config Sheet rev1.5_draft.xlsm (20171020) S2600BP_125 S2600BP_124 -Implement FSC Auto-configuraiton sheet 1.4 draft (20170822) S2600BP_123 -Implement FSC Auto-configuraiton sheet 1.3 release candidate (20170726) S2600BP_105 -Implement FSC Auto-configuraiton sheet 1.2 draft (20170609) -Add Liquid cooling sku S2600BPL support S2600BP_104 S2600BP_103 S2600BP_100 S2600BP_049 - Implement FSC Auto-configuraiton sheet 1.1 draft 050417 S2600BP_048 - Implement FSC Auto-configuraiton sheet 1.1 draft 04272017 S2600BP_047 S2600BP_046 S2600BP_045 - Implement FSC Auto-configuraiton sheet 1.0 S2600BP_044 S2600BP_043 S2600BP_042 - Implement FSC Auto-configuration sheet 1.0 Draft 12/28/16 - Support New HSPB H2204 - Add product ID 0x7C(SFP+) support S2600BP_041 S2600BP_040 S2600BP_039 S2600BP_038 S2600BP_037 S2600BP_036 S2600BP_035 S2600BP_034 S2600BP_033 S2600BP_032 S2600BP_031 - Add Buchanan Pass SFP+ + 2 Dual 10G Mother Board detection S2600BP_030 - Add FRU report for IFT carrier - Add Buchanan Pass SFP+ + 2 Dual 10G Mother Board FRU S2600BP_029 S2600BP_028 S2600BP_027 S2600BP_026 - Implement FSC configuration sheet 0.7 S2600BP_025 - Implement FSC configuration sheet 0.6 for H2224BNP Chassis S2600BP_024 - Implement FSC configuration sheet 0.6 for H2312BNP Chassis S2600BP_023 S2600BP_022 - Add NVMe 1 Therm Mgn,NVMe 1 Crit Warn sdr record - Add PT bridge board FRU record and PT bridge board detection (H91459-100-24HDD 6port Cable Pass Through Bridge board) - Add 6Port 12G SAS/NVMe combo bridge board (3008) H94462-200---24HDD support S2600BP_021 - Add FAN Auto detection feature for 3rd party chasis - Add Mem 1/2 VRD temp and EV CPU1 VR Temp SDR record S2600BP_020 - Add NVMe Enable/Disable Record - Add HSBP PBA Class Record S2600BP_019 - Add 2 BIOS Evt Sensor - Add BB CPU2 VR Temp SDR record S2600BP_018 - Remove un-supported PHI on Riser record. - Add 3008/3408 bridge board FRU record. - Add Riser 1/2 Temp sensor record. S2600BP_017 - Enable Auto Detect during SDR update - Remove P1 ERR2 and P2 ERR2 SDR record, Add CPU ERR2 SDR record - Remove S2600BP.FRU and Add S2600BPB.FRU for Buchanan Pass LBG 1G Dual 10G Mother board - Remvoe Redundant FAN SDR record, due to system doesn't support. S2600BP_016 -Add Buchanan Pass LBG L Dual 10G Mother board fru support (S2600BPQ.FRU) S2600BP_015 -Add Fan Redundancy sensor record S2600BP_014 -Add auto shutdown sensor record -Update Assertion Event Mask, Deassertion Event Mask and Reading Mask for FAN S2600BP_013 - Remove CPU ERR2 and Add P1 ERR2, P2 ERR2 record S2600BP_012 - Remove SDR Version record with FCT and FOQM tag. S2600BP_011 - Add PS1 Fan2 Fail and PS2 Fan2 Fail - Remove SDR Record which has SHIPPING, FOQM, NOT_USED tag(Except Version Record). S2600BP_010 - Implement FSC Auto config sheet 0.4 - Remove un-used SDR Record - Remove 2U4N_BP_X25 support S2600BP_009 - Implement FSC Auto config sheet 0.3 For BB MISC VR Temp, BB Outlet Temp and LAN MIC Temp - Implement PSU support for 2130W PSU only - Implement Chassis support for '2U4N_BP_X35' and '24HDDHSBP' S2600BP_007 S2600BP_006 - To add "Bad User PWD" sdr - Follow BNP FSC Auto-SDR Config Sheet rev02 to Add Fan Sensor Domain Map, Auto Profile,Test Plate FSC and OTHER S2600BP_005 -Follow BNP FSC Auto-SDR Config Sheet rev02 to Add H2312TP sheet S2600BP_004 -Follow BNP FSC Auto-SDR Config Sheet rev02 to Add DIMM thermal margin sensor. Add Global Clamp Curve Record Add Global Stepwise Header Records Add Global Clamp Record Add 2200W PS1 & PS2 Add System FAN sensor -Per Intel BKC team request add master_internal.cfg S2600BP_002 -Follow SDR spreadsheet rev 0.2 to update sensor in system configuration sheet S2600BP_0.1: - First release ============================================================================= REFERENCE MATERIAL ============================================================================= Common IBMC Firmware EAS Common Platform IBMC FW EPS [END OF RELEASE NOTES]